Introduction to MEG

Initialize NeuroAnalyzer
using NeuroAnalyzer

Magnetoencephalography (MEG) is a non-invasive method that measures the magnetic fields produced by the electrical activity of the brain. The same neural currents that generate the EEG (the postsynaptic currents of synchronously active cortical pyramidal neurons) also produce magnetic fields outside the head. They are extremely weak (10–1000 fT, i.e. \(10^{-14}\)–\(10^{-12}\) T, about \(10^{-9}\)–\(10^{-8}\) of the Earth’s magnetic field) and are measured with very sensitive sensors inside a magnetically shielded room.

MEG has the millisecond temporal resolution of EEG, and because magnetic fields pass the skull and scalp almost undistorted, a better spatial resolution for superficial sources.

Feature Description
Signal source intracellular (primary) currents of synchronously active pyramidal neurons, mainly postsynaptic dendritic currents
Temporal resolution milliseconds (as EEG)
Spatial resolution a few mm for superficial sources at high signal-to-noise ratio; worse for deep sources (depends on depth, SNR and the inverse method)
Invasiveness non-invasive, no electrodes on the head
Sensors SQUIDs (cooled with liquid helium) or optically pumped magnetometers
Environment magnetically shielded room

Physics of MEG

Sources

  • The primary source of MEG signals is the synchronous activity of the apical dendrites of pyramidal neurons, modeled as current dipoles.
  • A current produces a magnetic field circling around it (right-hand rule): a dipole tangential to the head surface produces a field that leaves the head on one side of the dipole and enters it on the other side, so the MEG topography of a dipole has two extrema, with the source between them.
  • MEG is most sensitive to tangential currents (e.g. in the walls of the sulci); radial currents (e.g. at the crowns of the gyri) produce no magnetic field outside a spherically symmetric conductor.
  • The magnetic field decreases quickly with the distance from the sensors, so MEG is less sensitive to deep sources than to superficial ones.

Maxwell’s equations

At the frequencies of brain activity, the electromagnetic fields can be treated as quasi-static (the time derivatives in Maxwell’s equations are negligible), so the magnetic field is determined by the currents through the Biot-Savart law. The magnetic field \(\mathbf{B}\) at the point \(\mathbf{r}\) produced by a current dipole \(\mathbf{Q}\) (primary current only, in an infinite homogeneous medium) is:

\[ \mathbf{B}(\mathbf{r}) = \frac{\mu_0}{4\pi} \frac{\mathbf{Q} \times \mathbf{R}}{|\mathbf{R}|^3} \]

where \(\mu_0\) is the permeability of free space, \(\mathbf{Q}\) the current dipole moment and \(\mathbf{R}\) the vector from the dipole to the measurement point. In a real head, the volume (return) currents also contribute; for a spherically symmetric conductor the field outside the head is given by the Sarvas formula, in which radial dipoles produce no field and the conductivities of the tissues do not matter.

Instrumentation

SQUIDs (superconducting quantum interference devices) are the most sensitive magnetic field detectors. They operate at the temperature of liquid helium (about 4 K, −269 °C), so the sensors are placed in a dewar (a vacuum-insulated vessel), 2–4 cm from the scalp.

  • DC-SQUIDs (two Josephson junctions, DC bias) are used in modern systems; RF-SQUIDs (one junction, radio-frequency readout) were used in early systems.
  • Each SQUID is coupled to a pickup coil:
    • magnetometers (a single loop) measure the field component perpendicular to the coil; most sensitive, also to distant sources and environmental noise
    • gradiometers measure the difference of the field between two loops: axial gradiometers (loops above each other, e.g. CTF systems) or planar gradiometers (loops side by side, e.g. MEGIN/Neuromag); they suppress distant (uniform) fields and are most sensitive to sources close to them; a planar gradiometer has its maximum directly above the source
  • Optically pumped magnetometers (OPMs) measure the field with laser light passing through a heated vapor of alkali atoms; they need no cryogenic cooling and can be placed directly on the scalp (higher signal, wearable systems that allow movements).

System components:

  1. Sensor array: 150–300 channels in a helmet-shaped dewar; e.g. the MEGIN (Elekta Neuromag) Vectorview and TRIUX systems have 102 sensor positions, each with one magnetometer and two orthogonal planar gradiometers (306 channels).
  2. Magnetically shielded room (MSR): layers of mu-metal (a high-permeability alloy, attenuating low-frequency fields) and aluminium (eddy-current shielding of higher frequencies) that attenuate the Earth’s field and environmental noise (traffic, elevators, power lines) by several orders of magnitude; some systems add active compensation (see Internal Active Shielding).
  3. Head position indicator (HPI) coils attached to the head, whose positions are measured by the MEG sensors (see Sensor geometry).
  4. Data acquisition: amplification and digitization, typically at 1–5 kHz; EEG, EOG, ECG and trigger channels are recorded simultaneously.
  5. Co-registration with MRI: the head shape and anatomical landmarks (nasion, preauricular points) are digitized and matched with the subject’s MRI for source localization.

MEG vs. EEG

Feature MEG EEG
Measures magnetic fields electric potential differences
Generators synchronous postsynaptic currents of pyramidal neurons the same
Sensitive to tangential, superficial sources radial and tangential sources, also deeper ones
Effect of the skull small (fields pass almost undistorted) strong (low skull conductivity smears the potentials)
Reference not needed (magnetometers measure the field directly) every channel depends on the reference
Temporal resolution milliseconds milliseconds
Spatial resolution better for superficial tangential sources lower
Sensor placement fixed helmet, 2–4 cm from the scalp (OPMs: on the scalp); the head position must be monitored electrodes on the scalp, move with the head
Subjects must stay still; fixed helmet size (a problem for children) flexible, portable, long recordings possible
Artifacts environmental magnetic noise, magnetic objects (implants, dental work), heart, eyes, muscles electrode and skin artifacts, eyes, muscles, heart
Cost high (helium, shielded room) low

MEG and EEG are complementary: they measure different aspects of the same neural currents, and their combination improves source localization.

Comparison with other methods:

Method Temporal resolution Spatial resolution Invasiveness Cost Measures
MEG milliseconds 2–5 mm (superficial sources) non-invasive high neural currents (magnetic fields)
EEG milliseconds 5–10 mm or worse non-invasive low neural currents (potentials)
fMRI seconds 1–3 mm non-invasive high blood oxygenation (BOLD)
PET minutes 4–6 mm radioactive tracer high metabolism, receptors
DTI (structural) 1–2 mm non-invasive high white matter tracts

Applications

Application Description
Epilepsy localizing interictal epileptic activity for surgical planning
Presurgical functional mapping localizing eloquent cortex (somatosensory, motor, auditory, visual, language areas)
Cognitive neuroscience perception, attention, memory, language, decision-making
Oscillations and connectivity brain rhythms and networks in source space
Clinical research autism, ADHD, schizophrenia, dementia, Parkinson’s disease, traumatic brain injury
Brain-computer interfaces real-time decoding (e.g. motor imagery)
Pharmacology effects of drugs on brain activity

Limitations: high cost and limited availability, sensitivity to magnetic noise and magnetic objects, the requirement to keep the head still (or to track and compensate its movements), low sensitivity to radial and deep sources, and the inverse problem of source localization.

Developments: on-scalp MEG with OPMs (wearable, closer to the brain), high-Tc SQUIDs cooled with liquid nitrogen, helium recycling, and integration with other modalities (EEG, MRI, brain stimulation).

MEG Signal Analysis

Preprocessing:

  1. Noise reduction: signal-space separation (SSS/tSSS, Maxwell filtering) and signal-space projection (SSP), see MEG noise reduction.
  2. Filtering, e.g. 0.1–100 Hz band-pass.
  3. Artifact removal: ICA or SSP (cardiac and ocular artifacts).
  4. Co-registration with MRI.

Source localization: estimating the location, orientation and strength of the neural sources:

  1. Equivalent current dipole (ECD): one or a few dipoles are fitted to the measured field (e.g. early sensory responses, epileptic spikes).
  2. Distributed source models, e.g. minimum-norm estimation (MNE, dSPM, sLORETA): currents are estimated on the whole cortical surface, suitable for multiple simultaneous sources.
  3. Beamformers (e.g. LCMV, DICS, SAM): spatial filters estimate the activity at each location while suppressing the other sources.

Analysis: evoked responses (event-related fields, ERFs, see ERPs/ERFs), power spectra and event-related synchronization/desynchronization (ERS/ERD), functional connectivity (e.g. coherence, imaginary coherence, phase-locking value) and effective connectivity (e.g. Granger causality), preferably in source space.

Processing MEG data in NeuroAnalyzer

Loading data

import_fiff() reads MEGIN (Elekta Neuromag) FIFF raw files (Vectorview, TRIUX, MaxFilter-processed and MNE-Python-saved files, including split files *_raw.fif, *_raw-1.fif, …). Signals are calibrated and converted to fT (magnetometers), fT/cm (gradiometers) and μV (EEG/EOG/EMG).

A 32-second TRIUX recording:

meg = import_fiff("files/meg/meg.fif")
info(meg)
              Data type: MEG
            File format: FIFF
            Source file: files/meg/meg.fif
         File size [MB]: 40.0
       Memory size [MB]: 80.41
                Subject: 2: Subject Subject
              Recording: TRIUX system
        Recording notes: 
         Recording date: 26-9-2016
         Recording time: 15:25:51
     Sampling rate (Hz): 1000
Signal length [samples]: 32000
Signal length [seconds]: 32.0
     Number of channels: 327
              Epochs ID: 
       Number of epochs: 1
 Epoch length [samples]: 32000
 Epoch length [seconds]: 32.0
         Line frequency: 50.0 Hz
                Markers: yes
      Channel locations: yes
 Number of MAG channels: 102
Number of GRAD channels: 204
 Number of EEG channels: 0

Channels:
 ch     label           type        unit    bad     
 ------ --------------- ----------- ------- -------
 1      IASX+           OTHER       V       false   
 2      IASX-           OTHER       V       false   
 3      IASY+           OTHER       V       false   
 4      IASY-           OTHER       V       false   
 5      IASZ+           OTHER       V       false   
 6      IASZ-           OTHER       V       false   
 7      IAS_DX          OTHER       V       false   
 8      IAS_DY          OTHER       V       false   
 9      IAS_X           OTHER       V       false   
 10     IAS_Y           OTHER       V       false   
 11     IAS_Z           OTHER       V       false   
 12     MEG 0111        MAG         fT      false   
 13     MEG 0112        GRAD        fT/cm   false   
 14     MEG 0113        GRAD        fT/cm   false   
 15     MEG 0121        MAG         fT      false   
 16     MEG 0122        GRAD        fT/cm   false   
 17     MEG 0123        GRAD        fT/cm   false   
 18     MEG 0131        MAG         fT      false   
 19     MEG 0132        GRAD        fT/cm   false   
 20     MEG 0133        GRAD        fT/cm   false   
 21     MEG 0141        MAG         fT      false   
 22     MEG 0142        GRAD        fT/cm   false   
 23     MEG 0143        GRAD        fT/cm   false   
 24     MEG 0211        MAG         fT      false   
 25     MEG 0212        GRAD        fT/cm   false   
 26     MEG 0213        GRAD        fT/cm   false   
 27     MEG 0221        MAG         fT      false   
 28     MEG 0222        GRAD        fT/cm   false   
 29     MEG 0223        GRAD        fT/cm   false   
 30     MEG 0231        MAG         fT      false   
 31     MEG 0232        GRAD        fT/cm   false   
 32     MEG 0233        GRAD        fT/cm   false   
 33     MEG 0241        MAG         fT      false   
 34     MEG 0242        GRAD        fT/cm   false   
 35     MEG 0243        GRAD        fT/cm   false   
 36     MEG 0311        MAG         fT      false   
 37     MEG 0312        GRAD        fT/cm   false   
 38     MEG 0313        GRAD        fT/cm   false   
 39     MEG 0321        MAG         fT      false   
 40     MEG 0322        GRAD        fT/cm   false   
 41     MEG 0323        GRAD        fT/cm   false   
 42     MEG 0331        MAG         fT      false   
 43     MEG 0332        GRAD        fT/cm   false   
 44     MEG 0333        GRAD        fT/cm   false   
 45     MEG 0341        MAG         fT      false   
 46     MEG 0342        GRAD        fT/cm   false   
 47     MEG 0343        GRAD        fT/cm   false   
 48     MEG 0411        MAG         fT      false   
 49     MEG 0412        GRAD        fT/cm   false   
 50     MEG 0413        GRAD        fT/cm   false   
 51     MEG 0421        MAG         fT      false   
 52     MEG 0422        GRAD        fT/cm   false   
 53     MEG 0423        GRAD        fT/cm   false   
 54     MEG 0431        MAG         fT      false   
 55     MEG 0432        GRAD        fT/cm   false   
 56     MEG 0433        GRAD        fT/cm   false   
 57     MEG 0441        MAG         fT      false   
 58     MEG 0442        GRAD        fT/cm   false   
 59     MEG 0443        GRAD        fT/cm   false   
 60     MEG 0511        MAG         fT      false   
 61     MEG 0512        GRAD        fT/cm   false   
 62     MEG 0513        GRAD        fT/cm   false   
 63     MEG 0521        MAG         fT      false   
 64     MEG 0522        GRAD        fT/cm   false   
 65     MEG 0523        GRAD        fT/cm   false   
 66     MEG 0531        MAG         fT      false   
 67     MEG 0532        GRAD        fT/cm   false   
 68     MEG 0533        GRAD        fT/cm   false   
 69     MEG 0541        MAG         fT      false   
 70     MEG 0542        GRAD        fT/cm   false   
 71     MEG 0543        GRAD        fT/cm   false   
 72     MEG 0611        MAG         fT      false   
 73     MEG 0612        GRAD        fT/cm   false   
 74     MEG 0613        GRAD        fT/cm   false   
 75     MEG 0621        MAG         fT      false   
 76     MEG 0622        GRAD        fT/cm   false   
 77     MEG 0623        GRAD        fT/cm   false   
 78     MEG 0631        MAG         fT      false   
 79     MEG 0632        GRAD        fT/cm   false   
 80     MEG 0633        GRAD        fT/cm   false   
 81     MEG 0641        MAG         fT      false   
 82     MEG 0642        GRAD        fT/cm   false   
 83     MEG 0643        GRAD        fT/cm   false   
 84     MEG 0711        MAG         fT      false   
 85     MEG 0712        GRAD        fT/cm   false   
 86     MEG 0713        GRAD        fT/cm   false   
 87     MEG 0721        MAG         fT      false   
 88     MEG 0722        GRAD        fT/cm   false   
 89     MEG 0723        GRAD        fT/cm   false   
 90     MEG 0731        MAG         fT      false   
 91     MEG 0732        GRAD        fT/cm   false   
 92     MEG 0733        GRAD        fT/cm   false   
 93     MEG 0741        MAG         fT      false   
 94     MEG 0742        GRAD        fT/cm   false   
 95     MEG 0743        GRAD        fT/cm   false   
 96     MEG 0811        MAG         fT      false   
 97     MEG 0812        GRAD        fT/cm   false   
 98     MEG 0813        GRAD        fT/cm   false   
 99     MEG 0821        MAG         fT      false   
 100    MEG 0822        GRAD        fT/cm   false   
 101    MEG 0823        GRAD        fT/cm   false   
 102    MEG 0911        MAG         fT      false   
 103    MEG 0912        GRAD        fT/cm   false   
 104    MEG 0913        GRAD        fT/cm   false   
 105    MEG 0921        MAG         fT      false   
 106    MEG 0922        GRAD        fT/cm   false   
 107    MEG 0923        GRAD        fT/cm   false   
 108    MEG 0931        MAG         fT      false   
 109    MEG 0932        GRAD        fT/cm   false   
 110    MEG 0933        GRAD        fT/cm   false   
 111    MEG 0941        MAG         fT      false   
 112    MEG 0942        GRAD        fT/cm   false   
 113    MEG 0943        GRAD        fT/cm   false   
 114    MEG 1011        MAG         fT      false   
 115    MEG 1012        GRAD        fT/cm   false   
 116    MEG 1013        GRAD        fT/cm   false   
 117    MEG 1021        MAG         fT      false   
 118    MEG 1022        GRAD        fT/cm   false   
 119    MEG 1023        GRAD        fT/cm   false   
 120    MEG 1031        MAG         fT      false   
 121    MEG 1032        GRAD        fT/cm   false   
 122    MEG 1033        GRAD        fT/cm   false   
 123    MEG 1041        MAG         fT      false   
 124    MEG 1042        GRAD        fT/cm   false   
 125    MEG 1043        GRAD        fT/cm   false   
 126    MEG 1111        MAG         fT      false   
 127    MEG 1112        GRAD        fT/cm   false   
 128    MEG 1113        GRAD        fT/cm   false   
 129    MEG 1121        MAG         fT      false   
 130    MEG 1122        GRAD        fT/cm   false   
 131    MEG 1123        GRAD        fT/cm   false   
 132    MEG 1131        MAG         fT      false   
 133    MEG 1132        GRAD        fT/cm   false   
 134    MEG 1133        GRAD        fT/cm   false   
 135    MEG 1141        MAG         fT      false   
 136    MEG 1142        GRAD        fT/cm   false   
 137    MEG 1143        GRAD        fT/cm   false   
 138    MEG 1211        MAG         fT      false   
 139    MEG 1212        GRAD        fT/cm   false   
 140    MEG 1213        GRAD        fT/cm   false   
 141    MEG 1221        MAG         fT      false   
 142    MEG 1222        GRAD        fT/cm   false   
 143    MEG 1223        GRAD        fT/cm   false   
 144    MEG 1231        MAG         fT      false   
 145    MEG 1232        GRAD        fT/cm   false   
 146    MEG 1233        GRAD        fT/cm   false   
 147    MEG 1241        MAG         fT      false   
 148    MEG 1242        GRAD        fT/cm   false   
 149    MEG 1243        GRAD        fT/cm   false   
 150    MEG 1311        MAG         fT      false   
 151    MEG 1312        GRAD        fT/cm   false   
 152    MEG 1313        GRAD        fT/cm   false   
 153    MEG 1321        MAG         fT      false   
 154    MEG 1322        GRAD        fT/cm   false   
 155    MEG 1323        GRAD        fT/cm   false   
 156    MEG 1331        MAG         fT      false   
 157    MEG 1332        GRAD        fT/cm   false   
 158    MEG 1333        GRAD        fT/cm   false   
 159    MEG 1341        MAG         fT      false   
 160    MEG 1342        GRAD        fT/cm   false   
 161    MEG 1343        GRAD        fT/cm   false   
 162    MEG 1411        MAG         fT      false   
 163    MEG 1412        GRAD        fT/cm   false   
 164    MEG 1413        GRAD        fT/cm   false   
 165    MEG 1421        MAG         fT      false   
 166    MEG 1422        GRAD        fT/cm   false   
 167    MEG 1423        GRAD        fT/cm   false   
 168    MEG 1431        MAG         fT      false   
 169    MEG 1432        GRAD        fT/cm   false   
 170    MEG 1433        GRAD        fT/cm   false   
 171    MEG 1441        MAG         fT      false   
 172    MEG 1442        GRAD        fT/cm   false   
 173    MEG 1443        GRAD        fT/cm   false   
 174    MEG 1511        MAG         fT      false   
 175    MEG 1512        GRAD        fT/cm   false   
 176    MEG 1513        GRAD        fT/cm   false   
 177    MEG 1521        MAG         fT      false   
 178    MEG 1522        GRAD        fT/cm   false   
 179    MEG 1523        GRAD        fT/cm   false   
 180    MEG 1531        MAG         fT      false   
 181    MEG 1532        GRAD        fT/cm   false   
 182    MEG 1533        GRAD        fT/cm   false   
 183    MEG 1541        MAG         fT      false   
 184    MEG 1542        GRAD        fT/cm   false   
 185    MEG 1543        GRAD        fT/cm   false   
 186    MEG 1611        MAG         fT      false   
 187    MEG 1612        GRAD        fT/cm   false   
 188    MEG 1613        GRAD        fT/cm   false   
 189    MEG 1621        MAG         fT      false   
 190    MEG 1622        GRAD        fT/cm   false   
 191    MEG 1623        GRAD        fT/cm   false   
 192    MEG 1631        MAG         fT      false   
 193    MEG 1632        GRAD        fT/cm   false   
 194    MEG 1633        GRAD        fT/cm   false   
 195    MEG 1641        MAG         fT      false   
 196    MEG 1642        GRAD        fT/cm   false   
 197    MEG 1643        GRAD        fT/cm   false   
 198    MEG 1711        MAG         fT      false   
 199    MEG 1712        GRAD        fT/cm   false   
 200    MEG 1713        GRAD        fT/cm   false   
 201    MEG 1721        MAG         fT      false   
 202    MEG 1722        GRAD        fT/cm   false   
 203    MEG 1723        GRAD        fT/cm   false   
 204    MEG 1731        MAG         fT      false   
 205    MEG 1732        GRAD        fT/cm   false   
 206    MEG 1733        GRAD        fT/cm   false   
 207    MEG 1741        MAG         fT      false   
 208    MEG 1742        GRAD        fT/cm   false   
 209    MEG 1743        GRAD        fT/cm   false   
 210    MEG 1811        MAG         fT      false   
 211    MEG 1812        GRAD        fT/cm   false   
 212    MEG 1813        GRAD        fT/cm   false   
 213    MEG 1821        MAG         fT      false   
 214    MEG 1822        GRAD        fT/cm   false   
 215    MEG 1823        GRAD        fT/cm   false   
 216    MEG 1831        MAG         fT      false   
 217    MEG 1832        GRAD        fT/cm   false   
 218    MEG 1833        GRAD        fT/cm   false   
 219    MEG 1841        MAG         fT      false   
 220    MEG 1842        GRAD        fT/cm   false   
 221    MEG 1843        GRAD        fT/cm   false   
 222    MEG 1911        MAG         fT      false   
 223    MEG 1912        GRAD        fT/cm   false   
 224    MEG 1913        GRAD        fT/cm   false   
 225    MEG 1921        MAG         fT      false   
 226    MEG 1922        GRAD        fT/cm   false   
 227    MEG 1923        GRAD        fT/cm   false   
 228    MEG 1931        MAG         fT      false   
 229    MEG 1932        GRAD        fT/cm   false   
 230    MEG 1933        GRAD        fT/cm   false   
 231    MEG 1941        MAG         fT      false   
 232    MEG 1942        GRAD        fT/cm   false   
 233    MEG 1943        GRAD        fT/cm   false   
 234    MEG 2011        MAG         fT      false   
 235    MEG 2012        GRAD        fT/cm   false   
 236    MEG 2013        GRAD        fT/cm   false   
 237    MEG 2021        MAG         fT      false   
 238    MEG 2022        GRAD        fT/cm   false   
 239    MEG 2023        GRAD        fT/cm   false   
 240    MEG 2031        MAG         fT      false   
 241    MEG 2032        GRAD        fT/cm   false   
 242    MEG 2033        GRAD        fT/cm   false   
 243    MEG 2041        MAG         fT      false   
 244    MEG 2042        GRAD        fT/cm   false   
 245    MEG 2043        GRAD        fT/cm   false   
 246    MEG 2111        MAG         fT      false   
 247    MEG 2112        GRAD        fT/cm   false   
 248    MEG 2113        GRAD        fT/cm   false   
 249    MEG 2121        MAG         fT      false   
 250    MEG 2122        GRAD        fT/cm   false   
 251    MEG 2123        GRAD        fT/cm   false   
 252    MEG 2131        MAG         fT      false   
 253    MEG 2132        GRAD        fT/cm   false   
 254    MEG 2133        GRAD        fT/cm   false   
 255    MEG 2141        MAG         fT      false   
 256    MEG 2142        GRAD        fT/cm   false   
 257    MEG 2143        GRAD        fT/cm   false   
 258    MEG 2211        MAG         fT      false   
 259    MEG 2212        GRAD        fT/cm   false   
 260    MEG 2213        GRAD        fT/cm   false   
 261    MEG 2221        MAG         fT      false   
 262    MEG 2222        GRAD        fT/cm   false   
 263    MEG 2223        GRAD        fT/cm   false   
 264    MEG 2231        MAG         fT      false   
 265    MEG 2232        GRAD        fT/cm   false   
 266    MEG 2233        GRAD        fT/cm   false   
 267    MEG 2241        MAG         fT      false   
 268    MEG 2242        GRAD        fT/cm   false   
 269    MEG 2243        GRAD        fT/cm   false   
 270    MEG 2311        MAG         fT      false   
 271    MEG 2312        GRAD        fT/cm   false   
 272    MEG 2313        GRAD        fT/cm   false   
 273    MEG 2321        MAG         fT      false   
 274    MEG 2322        GRAD        fT/cm   false   
 275    MEG 2323        GRAD        fT/cm   false   
 276    MEG 2331        MAG         fT      false   
 277    MEG 2332        GRAD        fT/cm   false   
 278    MEG 2333        GRAD        fT/cm   false   
 279    MEG 2341        MAG         fT      false   
 280    MEG 2342        GRAD        fT/cm   false   
 281    MEG 2343        GRAD        fT/cm   false   
 282    MEG 2411        MAG         fT      false   
 283    MEG 2412        GRAD        fT/cm   false   
 284    MEG 2413        GRAD        fT/cm   false   
 285    MEG 2421        MAG         fT      false   
 286    MEG 2422        GRAD        fT/cm   false   
 287    MEG 2423        GRAD        fT/cm   false   
 288    MEG 2431        MAG         fT      false   
 289    MEG 2432        GRAD        fT/cm   false   
 290    MEG 2433        GRAD        fT/cm   false   
 291    MEG 2441        MAG         fT      false   
 292    MEG 2442        GRAD        fT/cm   false   
 293    MEG 2443        GRAD        fT/cm   false   
 294    MEG 2511        MAG         fT      false   
 295    MEG 2512        GRAD        fT/cm   false   
 296    MEG 2513        GRAD        fT/cm   false   
 297    MEG 2521        MAG         fT      false   
 298    MEG 2522        GRAD        fT/cm   false   
 299    MEG 2523        GRAD        fT/cm   false   
 300    MEG 2531        MAG         fT      false   
 301    MEG 2532        GRAD        fT/cm   false   
 302    MEG 2533        GRAD        fT/cm   false   
 303    MEG 2541        MAG         fT      false   
 304    MEG 2542        GRAD        fT/cm   false   
 305    MEG 2543        GRAD        fT/cm   false   
 306    MEG 2611        MAG         fT      false   
 307    MEG 2612        GRAD        fT/cm   false   
 308    MEG 2613        GRAD        fT/cm   false   
 309    MEG 2621        MAG         fT      false   
 310    MEG 2622        GRAD        fT/cm   false   
 311    MEG 2623        GRAD        fT/cm   false   
 312    MEG 2631        MAG         fT      false   
 313    MEG 2632        GRAD        fT/cm   false   
 314    MEG 2633        GRAD        fT/cm   false   
 315    MEG 2641        MAG         fT      false   
 316    MEG 2642        GRAD        fT/cm   false   
 317    MEG 2643        GRAD        fT/cm   false   
 318    STI 001         MRK         V       false   
 319    STI 002         MRK         V       false   
 320    STI 003         MRK         V       false   
 321    STI 004         MRK         V       false   
 322    STI 005         MRK         V       false   
 323    STI 006         MRK         V       false   
 324    STI 007         MRK         V       false   
 325    STI 008         MRK         V       false   
 326    STI 101         MRK         V       false   
 327    SYS 201         OTHER               false   

Options:

  • allow_maxshield = true: import raw data recorded with internal active shielding (see below; refused by default).
  • channel_locs = :fiff (default): sensor/electrode positions from the file; :layout: bundled flattened 306-channel layout; :none: no locations.

Magnetometers and gradiometers channel indices:

first(meg.header.recording[:magnetometers], 5)
5-element Vector{Int64}:
 12
 15
 18
 21
 24
first(meg.header.recording[:gradiometers], 5)
5-element Vector{Int64}:
 13
 14
 16
 17
 19

Bad channels stored in the file (MNE-Python convention) are marked on import (none in this recording):

labels(meg)[meg.header.recording[:bad_channel]]
String[]

Sampling rate

MEG is usually recorded at 1–5 kHz (1000 Hz in this recording); the data are often downsampled after filtering.

Trigger channels: binary vs. combined

The channels STI001, STI002, …, STI016 are binary channels: each records one TTL line of the trigger interface, switching between 0 and 1.

The channels STI101 and STI102 are combined channels: they record the 16 binary lines of their trigger interface at once, as a decimal number. For example, if lines 1, 3 and 4 are high, the binary number is 1101 (from left to right: line 4 high, line 3 high, line 2 low, line 1 high), and the combined channel records the value 13. import_fiff() reads the events from the combined channel into meg.markers.

Sensor geometry and channel locations

Before each recording, the positions of the HPI coils (head position indicator; usually 3–5 coils attached to the head and digitized together with the head shape) are measured: a current with a known frequency is sent to each coil and its position is estimated from the magnetic field measured by the MEG sensors. This gives the position of the head relative to the sensors (the device → head transform). With continuous HPI (cHPI), the coils are active during the whole recording, so the head position can be tracked over time and head movements compensated (see Movement compensation).

The MEG header keeps the full sensor geometry needed for SSS, movement compensation and source modelling:

Field Content
:coil_loc one row per channel: coil center r0 (m) and coil frame ex, ey, ez (ez = coil normal); MEG in the device frame, EEG in the head frame
:coil_id FIFF coil type code (selects coil integration points)
:dev_head_t 4 × 4 device → head transform (empty for empty-room data)
:head_origin center of the sphere fitted to the head-shape digitization (head frame, m)
:hpi cHPI coil frequencies (:freqs) and digitized coil positions (:dig)

r0, ex, ey, ez of the first channel:

meg.header.recording[:coil_loc][1, :]
12-element Vector{Float64}:
 0.0
 0.0
 0.0
 1.0
 0.0
 0.0
 0.0
 1.0
 0.0
 0.0
 0.0
 1.0

Head transform:

meg.header.recording[:dev_head_t]
0×0 Matrix{Float64}

Channel locations (meg.locs) are taken from the file. MEG sensors are transformed to the head frame (RAS: x → right, y → anterior, z → superior). With at least 10 head-shape points, coordinates are centered on the fitted head sphere and divided by its radius, so EEG electrodes lie at radius ≈ 1 and MEG sensors at their true distance from the head. Otherwise the outermost MEG sensor is placed at radius 1.2 and the outermost EEG electrode at 1.0.

first(meg.locs, 5)
5×9 DataFrame
Row label loc_radius loc_theta loc_x loc_y loc_z loc_radius_sph loc_theta_sph loc_phi_sph
String Float64 Float64 Float64 Float64 Float64 Float64 Float64 Float64
1 MEG 0111 0.982558 163.548 -0.942328 0.278278 -0.434999 1.07454 163.548 -23.88
2 MEG 0112 0.982558 163.548 -0.942328 0.278278 -0.434999 1.07454 163.548 -23.88
3 MEG 0113 0.982558 163.548 -0.942328 0.278278 -0.434999 1.07454 163.548 -23.88
4 MEG 0121 0.997199 154.714 -0.901655 0.42594 -0.127296 1.00529 154.714 -7.27467
5 MEG 0122 0.997199 154.714 -0.901655 0.42594 -0.127296 1.00529 154.714 -7.27467

Locations can also be read without loading the data, from any FIFF file with measurement info, e.g. from an evoked (averaged) file:

locs = import_locs_fiff("files/meg/SSS/sample_audvis-ave.fif")
first(locs, 5)
5×9 DataFrame
Row label loc_radius loc_theta loc_x loc_y loc_z loc_radius_sph loc_theta_sph loc_phi_sph
String Float64 Float64 Float64 Float64 Float64 Float64 Float64 Float64
1 MEG 0113 1.13475 171.68 -1.1228 0.164209 -0.74014 1.35479 171.68 -33.1144
2 MEG 0112 1.13475 171.68 -1.1228 0.164209 -0.74014 1.35479 171.68 -33.1144
3 MEG 0111 1.13475 171.68 -1.1228 0.164209 -0.74014 1.35479 171.68 -33.1144
4 MEG 0122 1.20002 159.992 -1.12759 0.410583 -0.393983 1.26304 159.992 -18.1758
5 MEG 0123 1.20002 159.992 -1.12759 0.410583 -0.393983 1.26304 159.992 -18.1758

In a Vectorview/TRIUX helmet each magnetometer and its two planar gradiometers share one position, so three rows of locs have identical coordinates.

Plotting

Plotting signal:

NeuroAnalyzer.plot(meg; ch = "all", gui = false)

Plotting PSD of gradiometers:

plot_psd(meg; ch = "grad", gui = false)

Plotting PSD topomap of magnetometers:

plot_psd(meg; ch = "mag", type = :topo, gui = false)

Editing channels

delete_channel(), keep_channel(), add_channel(), rename_channel() and related functions keep all per-channel MEG header fields consistent: magnetometer/gradiometer lists, SSP channel mask and projection vectors, sensor geometry (:coil_loc, :coil_id) and locations.

mag = labels(meg)[meg.header.recording[:magnetometers]]
meg_mag = keep_channel(meg; ch = mag)

When a deleted channel is part of an SSP projector, its weights are removed from the projection vectors (a warning is shown).

MEG noise reduction

Brain signals measured with MEG are tiny (tens to hundreds of fT), while the environment produces fields that are many orders of magnitude larger: the Earth’s field, building vibrations, elevators, traffic, power lines. A magnetically shielded room removes most of it, but what remains is still often larger than the brain signal. In addition, there are interference sources close to the sensors: dental work, implants, eye and heart activity, and the system’s own internal active shielding.

Three related techniques remove such interference:

Method Main idea Uses Requires
SSP: signal-space projection remove known noise spatial patterns empty-room noise, ECG/EOG artifacts noise patterns (projection vectors)
SSS: signal-space separation separate fields from sources inside vs. outside the sensor helmet using physics environmental interference, bad channel reconstruction, head movement accurate sensor geometry and calibration
tSSS: temporal (spatiotemporal) SSS SSS + remove signals that appear in both the inside and the outside parts interference near the head (implants, dental work, stimulators) as SSS

SSS and tSSS are also called Maxwell filtering (they follow from Maxwell’s equations).

Status in NeuroAnalyzer:

  • SSP is available (generate_ssp_projectors(), apply_ssp_projectors()).
  • SSS, tSSS and movement compensation (maxwell_filter(), chpi_head_positions()) are available for MEGIN Vectorview/TRIUX data.
  • Data already processed with MEGIN MaxFilter or MNE-Python can be imported with import_fiff().

Signal-Space Projection

Signal-space projection (SSP) estimates a projection matrix that removes noise from a recording, using the spatial patterns of the noise measured without the signal of interest.

At any time point, the MEG measurement is a vector b with one value per channel. A source with a fixed position and orientation always produces the same spatial pattern across channels; only its amplitude changes over time. If we know the patterns of the noise sources, we can remove everything that lies along those patterns.

Let the noise patterns be the columns of a matrix. After orthonormalization (by SVD) they form a basis U of the noise subspace. The SSP operator is

\[ P = I - U U^T \]

and the cleaned data are \(b_{clean} = P b\). \(P\) is an orthogonal projector: it removes the components of the signal lying in the noise subspace and leaves everything orthogonal to it untouched.

Where do the noise vectors come from?

  • Empty-room recordings. A recording without a subject is decomposed with PCA. The first few components capture the dominant environmental noise. Neuromag systems store such vectors in the FIFF file (labels such as PCA-v1).
  • Artifacts. Average the data around heartbeats (ECG) or blinks (EOG) and take the main spatial components of that average.

Limitations:

  • Brain signal is also removed if it has a component along a noise pattern. With a few projectors this is a small loss, but it is not zero. Source estimation must use the same projector on the forward model.
  • Rank reduction. Each independent projection vector removes one dimension from the data.
  • Noise must be spatially stable. SSP cannot follow interference whose pattern changes, such as a moving head relative to a static noise source.
  • Projectors are tied to the data they were made for. After SSS/tSSS, previously computed projectors no longer describe the data and must not be applied.

SSP in NeuroAnalyzer

import_fiff() reads the projection vectors stored in a FIFF file into the recording header. The TRIUX recording above has no projectors; this 24-second Vectorview recording (MGH) has three empty-room PCA projectors:

raw = import_fiff("files/meg/test_raw.fif")
raw.header.recording[:ssp_labels]
3-element Vector{String}:
 "PCA-v1"
 "PCA-v2"
 "PCA-v3"

Number of channels covered by projectors:

count(raw.header.recording[:ssp_channels])
102

Size of the projection vectors (projections × channels):

size(raw.header.recording[:ssp_data])
(3, 102)

The projector and the number of independent projection vectors (the rank removed from the data):

p = generate_ssp_projectors(raw)
size(p.U, 2)
3

Applying the projector (all projections or selected ones):

raw_ssp = apply_ssp_projectors(raw)
raw_ssp12 = apply_ssp_projectors(raw; pidx = [1, 2])

apply_ssp_projectors!(raw) modifies the object in place.

The implementation follows MNE-Python:

  • All epochs are processed.
  • Bad channels are excluded from the projection vectors, so their artifacts do not spread to other channels.
  • Each vector is normalized to unit length.
  • Linearly dependent vectors (singular value < 1% of the largest) are discarded.
  • The projector is built in SI units (T, T/m) in which the vectors are defined, and converted to the units of the data (fT, fT/cm).

Mark bad channels before generating projectors. SSP is refused for MaxShield data and should not be applied after SSS (Maxwell filtering removes the projectors stored in the file).

Signal-Space Separation (SSS)

The MEG sensors sit in a thin shell around the head, between the head surface and the helmet’s outer surface. In that shell there are no currents. At the frequencies of interest (quasi-static approximation), Maxwell’s equations then say that the magnetic field can be written as the gradient of a scalar potential that satisfies Laplace’s equation. The solutions of Laplace’s equation in spherical coordinates are spherical harmonics, and they split naturally into two families:

  • Internal (inner) expansion: terms that decay as 1/r^(l+1) away from the expansion origin. They describe fields from sources inside the inner sphere, i.e. the brain.
  • External (outer) expansion: terms that grow as r^l. They describe fields from sources outside the outer sphere, i.e. the environment.

Any field in the sensor shell is the sum of an internal and an external part:

\[ b = S_{in} x_{in} + S_{out} x_{out} \]

S_in and S_out are computed from the sensor geometry alone (positions, orientations, coil shapes). The coefficients x_in, x_out are estimated from the data by least squares. The cleaned signal is reconstructed from the internal part only:

\[ b_{SSS} = S_{in} x_{in} \]

Unlike SSP, this needs no noise recording and makes no assumption about the noise pattern: anything consistent with an external source is removed. Mathematically it is an oblique projection, not an orthogonal one.

Expansion order

The expansions are truncated:

  • Internal order \(L_{in} = 8\) (default) → \((L_{in} + 1)^2 − 1 = 80\) components. Higher orders describe very fine spatial detail, dominated by sensor noise rather than brain signal.
  • External order \(L_{out} = 3\) (default) → \((L_{out} + 1)^2 − 1 = 15\) components. Environmental fields are spatially smooth, so few terms suffice.

\(80 + 15 = 95\) components are fitted to the ~306 sensor values of a Vectorview/TRIUX system. In practice regularization removes some weak internal components, so the data after SSS have a rank of roughly 70 instead of ~306. Rank-dependent analyses (ICA, beamformers, noise covariance estimation) must take this into account.

What SSS needs

  • Accurate sensor geometry and calibration. The method relies on knowing exactly where each sensor is and how it responds. Neuromag sites provide a fine-calibration file (sss_cal.dat) with corrected sensor orientations and gains, and a cross-talk file (ct_sparse.fif) describing coupling between the sensors of each triplet. Without them, suppression is clearly weaker.
  • Bad channels marked beforehand. A noisy or flat channel distorts the fit and spreads to all channels. Mark them first. After SSS, bad channels are reconstructed from the model, so interpolation is usually not needed.
  • Expansion origin. Usually the centre of a sphere fitted to the head shape (from digitisation), in head coordinates. For empty-room data (no head) the device origin is used.
  • Both magnetometers and gradiometers give the best separation.

Extra benefits

  • Movement compensation. With continuous head-position indicator (cHPI) coils, the head position is known over time. Because x_in describes the sources independently of the sensors, the internal field can be recomputed for a fixed reference head position. This corrects for head movement during the recording.
  • Head position transformation. Data from different runs or subjects can be transformed to a common head position.

Limitation: nearby interference

SSS separates inside from outside the two spheres. A source that sits between the inner sphere and the sensors, or very close to the head (dental work, implants, a magnetised object on the skin), does not fit cleanly into either expansion. Part of its field leaks into the internal component and survives SSS. This is the problem tSSS addresses.

Temporal (spatiotemporal) SSS

An artifact source close to the sensors leaks into both the internal and the external reconstructions, and the leaked parts share the same time course. Genuine brain activity appears only in the internal part.

Temporal (spatiotemporal) SSS (tSSS) therefore:

  1. Performs SSS and obtains internal and external signals.
  2. Splits the data into time windows (buffer length, e.g. 10 s).
  3. In each window, finds the temporal components that are common to the internal and external signals: subspace correlation above a threshold, typically 0.98.
  4. Removes those time courses from the internal signal by temporal projection.

Parameters

  • Buffer length (st_duration). Longer windows estimate the correlation more reliably and act as a high-pass filter at about 1 / st_duration Hz. 10 s is common (MaxFilter’s default); 4–10 s are used in practice. The buffer must be shorter than the recording, and ideally the recording length should be a multiple of the buffer.
  • Correlation limit (st_correlation). Lower values remove more; 0.98 is the usual default, 0.9 for strong artifacts.

When to use it

Use tSSS when there is interference near the head: magnetic implants, dental fillings or braces, deep brain stimulators, vagus nerve stimulators, or strong muscle artifacts. For clean data, SSS alone is often enough, and tSSS adds only a slight risk of removing brain activity that happens to correlate with external signals.

Internal Active Shielding

Many MEGIN systems can run with internal active shielding (IAS, MaxShield): compensation coils in the walls, floor and ceiling of the shielded room are driven by a feedback loop to cancel low-frequency environmental fields in real time. The coils can compensate the homogeneous fields \(B_x\), \(B_y\), \(B_z\) and the diagonal gradients \(\partial B_x / \partial x\), \(\partial B_y / \partial y\), \(\partial B_z / \partial z\); the feedback drives selected magnetometers of the helmet (on its right, left, front, rear and top) towards zero field.

The IAS channels can be recorded:

  • the currents through the individual coils, in room coordinates: IASX-, IASX+, IASY-, IASY+, IASZ-, IASZ+
  • virtual compensation channels representing the feedback that cancels the uniform field and the diagonal gradients, in head coordinates: IAS_X, IAS_Y, IAS_Z, IAS_DX, IAS_DY

The compensation coils produce fields of their own close to the helmet, so data recorded with IAS on (stored in maxshield_raw_data blocks) are distorted and not suitable for analysis without SSS. SSS removes the compensation fields together with the rest of the external interference.

NeuroAnalyzer refuses such files by default:

obj = import_fiff("ias_on_raw.fif")

Gives error: ... contains raw MaxShield data (internal active shielding was on) ...

To import anyway, e.g. for inspection:

obj = import_fiff("ias_on_raw.fif"; allow_maxshield = true)
obj.header.recording[:maxshield] # true

Objects flagged with :maxshield => true are rejected by generate_ssp_projectors() and apply_ssp_projectors(), because SSP cannot correct IAS distortion.

Order of operations

A typical Neuromag/MEGIN pipeline:

  1. Import and inspect raw data. Do not apply stored SSP projectors yet.
  2. Mark bad channels (noisy, flat, flux jumps).
  3. SSS or tSSS, with fine calibration, cross-talk correction and, if cHPI was used, movement compensation.
  4. Filtering, resampling.
  5. Artifact removal on the SSS-processed data: new ECG/EOG SSP projectors computed from these data, or ICA (with the number of components ≤ data rank).
  6. Epoching, averaging, source analysis. The forward model must include the same SSS/SSP operations.

Rules of thumb:

  • Never apply SSP projectors computed before SSS to SSS-processed data. They describe noise patterns of the unprocessed data. MNE-Python removes them during Maxwell filtering. If you want empty-room projectors to contribute, include them in the SSS model rather than applying them afterwards.
  • SSP without SSS is fine for systems or data where SSS is unavailable (e.g. no calibration files), and for ECG/EOG artifacts.
  • Account for the reduced rank after SSS (~70) and after each SSP vector.

Maxwell filtering in NeuroAnalyzer

maxwell_filter() and chpi_head_positions() support MEGIN Vectorview and TRIUX data imported with import_fiff() (they need the sensor geometry, head origin and cHPI information stored at import). They are new; compare results with MaxFilter or MNE-Python before relying on them.

Calibration files

The fine-calibration (sss_cal.dat) and cross-talk (ct_sparse.fif) files are specific to each MEG system: they are provided with the system (in a MaxFilter installation, usually /neuro/databases/sss/sss_cal.dat and /neuro/databases/ctc/ct_sparse.fif) and must be used only with data recorded on that system. The recording test_raw.fif comes from the Vectorview system at MGH, whose files are:

sss_cal_file = "files/meg/SSS/sss_cal_mgh.dat"
cross_talk_file = "files/meg/SSS/ct_sparse_mgh.fif"

1. Mark bad channels

Bad channels are excluded from the expansion and reconstructed by it, so they must be marked first (noisy, flat or jumping channels found by inspection; automatic detection is not yet available). For example:

bad = get_channel(raw; ch = ["MEG 2443"])
raw.header.recording[:bad_channel][bad] .= true

2. SSS

raw_sss = maxwell_filter(raw;
                         int_order = 8,               # internal order
                         ext_order = 3,               # external order
                         origin = :auto,              # fitted head sphere
                         regularize = :in,            # :none to disable
                         calibration = sss_cal_file,  # fine calibration
                         cross_talk = cross_talk_file)

If the head origin cannot be estimated (fewer than 10 digitization points), set it explicitly in meters, e.g. origin = [0.0, 0.0, 0.04].

Gradiometers before (blue) and after (black) SSS:

NeuroAnalyzer.plot(raw, raw_sss; ch = "grad", seg = (5, 10), gui = false)

3. tSSS

Same function, with a temporal buffer:

raw_tsss = maxwell_filter(raw;
                          st_duration = 10.0,      # buffer (s)
                          st_correlation = 0.98,   # correlation limit
                          calibration = sss_cal_file,
                          cross_talk = cross_talk_file)

Result

After Maxwell filtering:

  • :sss => true (and :tsss => true for tSSS) are set in the recording header;
  • :sss_info holds the processing parameters, including the number of internal components used, which is the rank of the MEG data;
  • bad MEG channels are reconstructed and marked as good;
  • SSP projectors present before SSS are removed;
  • the :maxshield flag is cleared;
  • fine-calibrated sensor geometry is stored and :dev_head_t is set to the destination head position.

The rank of the data after SSS (needed e.g. for ICA and covariance estimation):

raw_sss.header.recording[:sss_info][:rank]
73

Maxwell filtering can be applied only once; data must be continuous (one epoch). Epoch the data after filtering. maxwell_filter!() modifies the object in place.

Movement compensation

If cHPI coils were active during the recording, the header contains their frequencies and digitized positions. A 17-second Vectorview recording with five cHPI coils:

chpi = import_fiff("files/meg/SSS/chpi5_raw.fif")
chpi.header.recording[:hpi][:freqs]
5-element Vector{Float64}:
 261.3330078125
 278.0
 294.6669921875
 311.3330078125
 328.0

Estimate the head position over time (one row per window: time, rotation quaternion q1–q3, translation x, y, z in m of the device → head transform, goodness of fit, coil position error in m, velocity in m/s):

head_pos = chpi_head_positions(chpi;
                               t_window = 0.2,      # window length (s)
                               t_step = 0.1,        # step (s)
                               gof_limit = 0.98,    # minimum goodness of fit
                               dist_limit = 0.005)  # maximum coil error (m)

Total head displacement relative to the start of the recording:

xyz = head_pos[:, 5:7]
d = 1000 .* sqrt.(sum((xyz .- xyz[1:1, :]) .^ 2; dims = 2))
println("maximum displacement: ", round(maximum(d); digits = 1), " mm")
maximum displacement: 7.5 mm

Apply SSS/tSSS with movement compensation; the data are transformed to the initial head position (or to destination, a 4 × 4 device → head transform or a translation vector in m). The fine-calibration and cross-talk files of this system are not available, so they are omitted:

chpi_mc = maxwell_filter(chpi; head_pos = head_pos)

Empty-room recordings

An empty-room recording (without a subject) is usually measured before or after the experiment; it characterizes the environmental and sensor noise (e.g. for SSP projectors or for the noise covariance in source localization). An empty-room recording from the MGH system:

er = import_fiff("files/meg/empty_room_raw.fif")

Gradiometers:

plot_psd(er; ch = "grad", flim = (0, 300), gui = false)

Magnetometers:

plot_psd(er; ch = "mag", flim = (0, 300), gui = false)

Without a head, the expansion is done in the device frame (coord_frame = :meg):

er_sss = maxwell_filter(er;
                        coord_frame = :meg,
                        calibration = sss_cal_file,
                        cross_talk = cross_talk_file)

References

  1. Uusitalo MA, Ilmoniemi RJ. Signal-space projection method for separating MEG or EEG into components. Med Biol Eng Comput. 1997;35(2):135–140. doi:10.1007/BF02534144
  2. Taulu S, Kajola M. Presentation of electromagnetic multichannel data: the signal space separation method. J Appl Phys. 2005;97(12):124905. doi:10.1063/1.1935742
  3. Taulu S, Simola J. Spatiotemporal signal space separation method for rejecting nearby interference in MEG measurements. Phys Med Biol. 2006;51(7):1759–1768. doi:10.1088/0031-9155/51/7/008